Q49. A reinforced coating is

 
 
 
 

Q50. The Inspectors’ goal at the Pre-Job Conference is to:

 
 
 
 

Q51. As a NACE Level 2 Inspector on a field job; prior to submission your documentation should always reviewed and approved by:

 
 
 
 

Q52. A single component water borne acrylic coating cures by:

 
 
 
 

Q53. Differences in technique for abrasive blasting concrete versus steel require the operator to:

 
 
 
 

Q54. An Inspection and Test Plan is required when:

 
 
 
 

Q55. You are the NACY Coating Inspector on a tank lining project where desiccant dehumidification is being used. Since the first shift of abrasive blasting your readings have indicated relative humidity below 40%; however on the second shift of coating application your readings are indicting 80%.
Your FIRST preferred course of action is to:

 
 
 
 

Q56. When observing fabrication defects the NACE Inspector should:

 
 
 
 

Q57. Galvanizing performs best in which of the following exposures:

 
 
 
 

Q58. When performing inspection in accordance with ASTM D 4138 the Inspector will use:

 
 
 
 

Q59. Individuals conducting Coating Surveys should:

 
 
 
 

Q60. When completing the Final Inspection report the Inspector should write the report using:

 
 
 
 

Q61. Because a NACE Level 2 Inspector has been trained in specific destructive tests, it is up to the Inspector to decide if and when a destructive test is required.

 
 

Q62. Corrosion is the reverse process of

 
 
 
 

Q63. Dehumidification is defined as the removal of moisture vapor from the air to

 
 
 
 

Q64. You are NACE Level 2 Inspector working on a tank lining job where a mobile centrifugal blast unit is being used to blast the tank floor to a NACE No.1/SSPC SP 5. The Contractor has completed his final blast and has called for a hold point inspection. This is the 1 st time you have seen field based centrifugal blast cleaning. You observe what appears to be staining on the substrate however the Contractor assures you this is normal when using centrifugal blast units and what you are seeing is what is defined in the standard as an acceptable variation in appearance.
Your FIRST preferred course of action is to:

 
 
 
 

Q65. NACE/SSPC Water Jetting standards are directly equivalent to ISO Abrasive Blast Standards:

 
 

Q66. Inspection and Test plans are developed by referencing:

 
 
 
 

Q67. Centrifugal blast cleaning requires:

 
 
 
 

The NACE NACE-CIP2-001 exam consists of two parts: a written exam and a practical exam. The written exam consists of 120 multiple-choice questions that cover the various topics related to coatings inspection. The practical exam involves hands-on testing of the candidate’s ability to perform coating inspections and quality control procedures. The practical exam is conducted in a laboratory setting and requires the candidate to demonstrate their proficiency in using various inspection tools and equipment.

NACE-CIP2-001 Exam is recognized as a standard for coating inspection certification in many industries, including oil and gas, petrochemical, marine, and construction. Coating Inspector Level 2 certification is highly respected and is often used as a requirement for employment in the coating industry. Achieving this certification demonstrates a high level of expertise and commitment to the industry, making it a valuable asset for professionals in this field.

 